Whirlpool Ventilation Hood GZ8330XL User Manual

®
Convertible Range Hood  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
1-1/2"  
GZ8330XL  
GZ8336XL  
(3.8 cm)  
12"  
1"  
(2.5 cm)  
(30.5 cm)  
9"  
(22.9 cm)  
2"  
(5.1 cm)  
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.  
electrical supply. Use copper wire only. A time-  
delay fuse or circuit breaker and separate circuit is  
recommended.  
9"  
(22.9 cm)  
3/4"  
(1.9 cm)  
1-1/2"  
(3.8 cm)  
3/8"  
(9.5 mm)  
7-1/2"  
(19.1 cm)  
29-7/8" (75.9 cm) model: GZ8330  
35-7/8" (91.1 cm) model: GZ8336  
20"  
(50.8 cm)  
VENTING REQUIREMENTS  
7" (17.8 cm) round  
or 3-1/4" x 10"  
(8.3 x 25.4 cm)  
roof cap  
7" (17.8 cm) round  
or 3-1/4" x 10"  
(8.3 x 25.4 cm)  
through the wall  
through roof  
Vertical  
roof venting  
Horizontal  
wall venting  
Round vent: Use 7"  
(17.8 cm) round damper  
(purchased separately)  
wall  
cap  
3-1/4" x 10"  
(8.3 x 25.4 cm)  
through the wall  
24" (61.0 cm) to  
30" (76.2 cm) above  
cooking surface  
24" (61.0 cm) to  
30" (76.2 cm) above  
cooking surface  
3-1/4" x 10" (8.3 x 25.4 cm) vent system  
7" (17.8 cm) vent system  
3-1/4" x 10"  
(8.3 x 25.4 cm)  
elbow  
wall cap  
90° elbow  
6 ft. (1.8 m)  
6 ft. ( 1.8 m)  
wall cap  
2 ft. (0.6 m)  
Maximum length  
=
70 ft.  
(21.3 m)  
Maximum length  
1 - 90° elbow  
8 ft. (2.4 m) straight  
1 - wall cap  
Length of 3-1/4" x  
10" (8.3 x 25.4 cm)  
system  
= 70 ft.  
(21.3 m)  
1 - 90° elbows  
1 - wall cap  
8 ft. (2.4 m) straight  
Length of 7"  
(17.8 cm) system  
=
=
=
5 ft.  
0 ft.  
8 ft.  
(1.5 m)  
(0 m)  
(2.4 m)  
=
=
=
5 ft.  
8 ft.  
0 ft.  
(1.5 m)  
(2.4 m)  
(0 m)  
2 ft.  
(0.6 m)  
=
13 ft.  
(3.9 m)  
= 13 ft.  
(3.9 m)  
Recommended standard fittings  
Recommended standard fittings  
3-1/4" x 10"  
(8.3 x 25.4 cm) to (8.3 x 25.4 cm)  
7" (17.8 cm) =  
4.5 ft. (1.4 m)  
3-1/4" x 10"  
90° elbow =  
5 ft. (1.5 m)  
45° elbow =  
7" (17.8 cm)  
2.5 ft. (0.8 m) wall cap =  
0 ft. (0 m)  
3-1/4" x 10"  
(8.3 x 25.4 cm)  
flat elbow =  
12 ft. (3.7 m)  
3-1/4" x 10"  
(8.3 x 25.4 cm)  
wall cap =  
3-1/4" x 10"  
(8.3 x 25.4 cm)  
90° elbow =  
5 ft. (1.5 m)  
to 7" (17.8 cm)  
90° elbow =  
5 ft. (1.5 m)  
0 ft. (0 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8285188  
07-20-02  
 

Westinghouse Convection Oven WST3019ZE User Manual
Westinghouse Fan WHO4 User Manual
Whirlwind Music Mixer MPM 1 User Manual
Wizcom Scanner 3 Lite User Manual
Woodstock Saw M1013 User Manual
Yamaha Automobile Parts F25 User Manual
Zanussi Range ZKT 641 H User Manual
Zanussi Refrigerator 102233 User Manual
Zanussi Washer FLA 1001 W User Manual
Zebra Technologies Printer PR4T User Manual